Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL WIRE > BUILDING WIRE / NM
Sort By:
1 2
Romex SIMpull 14/2NM-WGX25 Building Wire Romex SIMpull 12/2NM-WGX25 Building Wire Romex SIMpull 14/2NM-WGX50 Building Wire
Romex? Building Wire, NM-B, Wire Size: 14 AWG, 25 ft L, Number of Conductors: 2, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: White, Sheath Diameter: 0.372 in, 600 V, 15 A, Resistance: 2.631 Ohm, Bend Radius: 0.8 in, Operating Temperature: 90 deg C Southwire? Romex? Type NM-B Building Wire, Wire Size: 12 AWG, 25 ft L, Number of Conductors: 2, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Sheath Material: Nylon, Sheath Color: Yellow, 600 V, 20 A, Operating Temperature: 90 deg C Romex? Building Wire, NM-B, Wire Size: 14 AWG, 50 ft L, Number of Conductors: 2, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: White, Sheath Diameter: 0.372 x 0.176 in, 600 V, 15 A, Resistance: 2.631 Ohm, Bend Radius: 0.8 in, Operating Temperature: 90 deg C
Romex SIMpull 14/3NM-WGX25 Building Wire Romex SIMpull 12/2NM-WGX50 Building Wire Romex SIMpull 14/3NM-WGX50 Building Wire
Southwire? Romex? Building Wire, Type NM-B, THHN, Wire Size: 14 AWG, 25 ft L, Number of Conductors: 3, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Pink, 600 V, 15 A, Operating Temperature: 90 deg C, Includes: Ground Wire Romex? Building Wire, NM-B, Wire Size: 12 AWG, 50 ft L, Number of Conductors: 2, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Yellow, Sheath Diameter: 0.422 in, 600 V, 20 A, Resistance: 1.662 Ohm, Bend Radius: 1 in, Operating Temperature: 90 deg C Southwire? Romex? Building Wire, Type NM-B, Wire Size: 14 AWG, 50 ft L, Number of Conductors: 3, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Blue, Sheath Diameter: 19 mil, 600 V, 15 A, Operating Temperature: 90 deg C, Includes: Ground Wire
Romex SIMpull 12/3NM-WGX25 Building Wire Romex SIMpull 14/2NM-WGX100 Building Wire Romex SIMpull 10/2NM-WGX25 Building Wire
Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National electric Code Article 336. Dwellings not exceeding 3 floors above-grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Romex? Building Wire, NM-B, THHN, Wire Size: 14 AWG, 100 ft L, Number of Conductors: 2, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: White, Sheath Diameter: 19 mil, Bedding Material: Kraft Paper, 600 V, 15 A, Resistance: 2.631, 3.17 Ohm, Bend Radius: 0.8 in, Operating Temperature: 90 deg C, Includes: Ground Wire Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National electric Code Article 336. Dwellings not exceeding 3 floors above-grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.
Romex SIMpull 12/2NM-WGX100 Building Wire Romex SIMpull 12/3NM-WGX50 Building Wire Romex SIMpull 14/2NM-WGX250 Building Wire
Romex? Building Wire, NM-B, THHN, Wire Size: 12 AWG, 100 ft L, Number of Conductors: 2, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Yellow, Sheath Diameter: 0.422 x 0.19 in, 600 V, 20 A, Resistance: 1.662 Ohm, Bend Radius: 1 in, Operating Temperature: 90 deg C Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National electric Code Article 336. Dwellings not exceeding 3 floors above-grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Romex? Building Wire, NM-B, THHN, Wire Size: 14 AWG, 250 ft L, Number of Conductors: 2, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: White, Sheath Diameter: 0.372 x 0.176 in, 600 V, 15 A, Resistance: 2.631 Ohm, Bend Radius: 0.8 in, Operating Temperature: 90 deg C
Romex SIMpull 10/3NM-WGX25 Building Wire Romex SIMpull 14/3NM-WGX100 Building Wire Romex SIMpull 10/2NM-WGX50 Building Wire
Southwire? Romex? Non-Metallic Cable, Wire Size: 10 AWG, 25 ft L, Number of Conductors: 3, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, 600 V, 30 A, Resistance: 1.040 to 1.253 Ohm, Bend Radius: 1.3 in, Operating Temperature: 90 deg C Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National electric Code Article 336. Dwellings not exceeding 3 floors above-grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the national Electric Code Article 336. Dwellings not exceeding three floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.
Romex SIMpull 14/3NM-WGX250 Building Wire Romex SIMpull 12/3NM-WGX100 Type NM-B Building Wire Romex SIMpull 12/2NM-WGX250 Building Wire
Southwire? Romex? Building Wire, NM-B, THHN, Wire Size: 14 AWG, 250 ft L, Number of Conductors: 3, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Blue, Sheath Diameter: 19 mil, 600 V, 15 A, Operating Temperature: 90 deg C, Includes: Ground Wire Southwire? Romex? Sheathed Cable, NM-B, Wire Size: 12 AWG, 100 ft L, Number of Conductors: 3, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Purple, 600 V, 20 A, Operating Temperature: 90 deg C Romex? Building Wire, NM-B, Wire Size: 12 AWG, 250 ft L, Number of Conductors: 2, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Yellow, Sheath Diameter: 0.422 in, 600 V, 20 A, Resistance: 1.662 Ohm, Bend Radius: 1 in, Operating Temperature: 90 deg C
Romex SIMpull 10/3NM-WGX50 Building Wire Romex SIMpull 10/2NM-WGX100 Type NM-B Building Wire Romex SIMpull 12/3NM-WGX250 Type NM-B Building Wire
Southwire? Romex? Building Wire, Type NM-B, Wire Size: 10 AWG, 50 ft L, Number of Conductors: 3, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Pink, 600 V, 30 A, Operating Temperature: 90 deg C Southwire? Romex? Building Wire, Type NM-B, THHN, Wire Size: 10 AWG, 100 ft L, Number of Conductors: 2, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Orange, Sheath Diameter: 24 mil, 600 V, 30 A, Operating Temperature: 90 deg C, Includes: Ground Wire Southwire? Romex? Brand SIMpull (nonmetallic-sheathed) cable may be used for both exposed and concealed work in dry locations with ampacity limited to that for 60 deg C conductors as specified in the National Electrical Code (NEC). Individual conductor insulation is rated 90 deg C as required by the NEC and by the UL product standard (UL 719) for terminations in lighting fixtures. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B cable is 600 V. Individual conductors within Type NM-B cable are not listed or marked as THHN conductors (or any other NEC recognized conductor type) and are not permitted to be installed apart from the complete Type NM-B cable. Conductors routed inside panelboards and boxes (without the cable jacket) for termination therein are considered part of the complete Type NM-B cable.
Romex SIMpull 10/3NM-WGX100 Type NM-B Building Wire Romex SIMpull 8/2NM-WGX125 Type NM-B Building Wire Romex SIMpull 10/2NM-WGX250 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the national Electric Code Article 336. Dwellings not exceeding three floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the national Electric Code Article 336. Dwellings not exceeding three floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Romex? Building Wire, NM-B, Wire Size: 10 AWG, 250 ft L, Number of Conductors: 2, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Orange, Sheath Diameter: 0.505 in, 600 V, 30 A, Resistance: 1.04 Ohm, Bend Radius: 1.2 in, Operating Temperature: 90 deg C
Romex SIMpull 28827472 Type NM-B Building Wire Romex SIMpull 10/3NM-WGX250 Type NM-B Building Wire Romex SIMpull 6/2NM-WGX125 Type NM-B Building Wire
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the national Electrical Code 1. May be run in-air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 V. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544 and requirements of the national Electrical Code. Southwire? Romex? brand SIMpull NM-B (non-metallic sheathed) cable may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the national electrical code. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B cable is 600 V. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the national Electric Code Article 336. Dwellings not exceeding three floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.
Romex SIMpull 8/3NM-WGX125 Type NM-B Building Wire Romex SIMpull 14/2NM-WGX1000 Type NM-B Building Wire Romex SIMpull 63947672 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the national Electric Code Article 336. Dwellings not exceeding three floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the national Electric Code Article 336. Dwellings not exceeding three floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the national Electrical Code 1. May be run in-air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 V. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544 and requirements of the national Electrical Code.
   
 
1 2